Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J. bras. pneumol ; 36(1): 29-36, jan.-fev. 2010. tab, ilus
Article in English | LILACS | ID: lil-539432

ABSTRACT

OBJECTIVE: To determine the interobserver and intraobserver agreement in the diagnosis of interstitial lung diseases (ILDs) based on HRCT scans and the impact of observer expertise, clinical data and confidence level on such agreement. METHODS: Two thoracic radiologists and two general radiologists independently reviewed the HRCT images of 58 patients with ILDs on two distinct occasions: prior to and after the clinical anamnesis. The radiologists selected up to three diagnostic hypotheses for each patient and defined the confidence level for these hypotheses. One of the thoracic and one of the general radiologists re-evaluated the same images up to three months after the first readings. In the coefficient analyses, the kappa statistic was used. RESULTS: The thoracic and general radiologists, respectively, agreed on at least one diagnosis for each patient in 91.4 percent and 82.8 percent of the patients. The thoracic radiologists agreed on the most likely diagnosis in 48.3 percent (κ = 0.42) and 62.1 percent (κ = 0.58) of the cases, respectively, prior to and after the clinical anamnesis; likewise, the general radiologists agreed on the most likely diagnosis in 37.9 percent (κ = 0.32) and 36.2 percent (κ = 0.30) of the cases. For the thoracic radiologist, the intraobserver agreement on the most likely diagnosis was 0.73 and 0.63 prior to and after the clinical anamnesis, respectively. That for the general radiologist was 0.38 and 0.42.The thoracic radiologists presented almost perfect agreement for the diagnostic hypotheses defined with the high confidence level. CONCLUSIONS: Interobserver and intraobserver agreement in the diagnosis of ILDs based on HRCT scans ranged from fair to almost perfect and was influenced by radiologist expertise, clinical history and confidence level.


OBJETIVO: Determinar a concordância interobservador e intraobservador no diagnóstico de doenças pulmonares intersticiais (DPIs) por TCAR e o impacto da experiência dos observadores, dos dados clínicos e do grau de confiança nessas concordâncias. MÉTODOS: Dois radiologistas torácicos e dois gerais independentemente avaliaram imagens de TCAR de 58 pacientes com DPIs em dois momentos: antes e após da anamnese clínica. Os observadores selecionaram até três hipóteses diagnósticas para cada paciente e definiram o grau de confiança dessas hipóteses. Um dos radiologistas torácicos e um dos gerais reavaliaram as mesmas imagens até três meses após a primeira leitura. As análises estatísticas foram feitas utilizando o coeficiente kappa. RESULTADOS: Os radiologistas torácicos e os gerais, respectivamente, concordaram com uma ou mais hipóteses diagnósticas em 91,4 por cento e 82,8 por cento dos pacientes. Os radiologistas torácicos concordaram com o diagnóstico mais provável em 48,3 por cento (κ = 0,42) e 62,1 por cento (κ = 0,58) dos casos, respectivamente, antes e após a anamnese clínica; de forma semelhante; os radiologistas gerais concordaram com o diagnóstico mais provável em 37,9 por cento (κ = 0,32) e 36,2 por cento (κ = 0,30). A concordância intraobservador do radiologista torácico no diagnóstico mais provável foi de 0,73 e 0,63, antes e após da anamnese clínica, respectivamente; para o radiologista geral, essa foi de 0,38 e 0,42. Os radiologistas torácicos apresentaram graus de concordância quase perfeitos nas hipóteses diagnósticas definidas com o grau de confiança alto. CONCLUSÕES: A concordância interobservador e intraobservador no diagnóstico das DPIs por TCAR variaram de regular a quase perfeita, tendo sido influenciadas pela experiência do radiologista, pela história clínica e pelo grau de confiança.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Clinical Competence , Lung Diseases, Interstitial , Radiology/education , Tomography, X-Ray Computed/statistics & numerical data , Data Interpretation, Statistical , Observer Variation
2.
Radiol. bras ; 41(6): 355-360, nov.-dez. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-507114

ABSTRACT

OBJETIVO: Estabelecer o valor das seqüências ponderadas em T2 para diferenciar cistos simples de hemangiomas hepáticos. MATERIAIS E MÉTODOS: Estudo prospectivo, observacional, transversal e duplo-cego em 52 pacientes com 91 lesões hepáticas (34 cistos simples e 57 hemangiomas) submetidos a ressonância magnética de abdome. A análise conjunta de todas as seqüências realizadas foi considerada o padrão-ouro. Dois observadores independentes avaliaram, subjetivamente, as seqüências TSE com TE longo e B-FFE, procurando diferenciar cistos de hemangiomas. Foram calculadas a eficácia das seqüências e a concordância interobservador e intra-observador por meio do teste kappa (κ) (p < 0,05*). RESULTADOS: As dimensões dos cistos variaram entre 0,5 e 6,5 cm (média de 1,89 cm) e as dos hemangiomas, entre 0,8 e 11 cm (média de 2,62 cm). A concordância entre a avaliação da seqüência com TE longo e o padrão-ouro foi insignificante (κ: 0,00-0,10). A concordância entre a avaliação da seqüência B-FFE e o padrão-ouro variou de substancial (κ: 0,62-0,71) a quase perfeita (κ: 0,86) para ambos os examinadores. A concordância interobservador e intra-observador para a seqüência B-FFE variou entre substancial (κ: 0,62-0,70) e quase perfeita (κ: 0,85-0,91). CONCLUSÃO: A técnica B-FFE apresenta eficácia e reprodutibilidade elevadas na diferenciação de cistos e hemangiomas.


OBJECTIVE: To establish the role of MRI T2-weighted sequences in the differentiation between simple cysts and hepatic hemangiomas. MATERIALS AND METHODS: A double-blinded, prospective, observational, cross-sectional study evaluated 52 patients with 91 hepatic lesions (34 simple cysts and 57 hemangiomas) submitted to abdominal magnetic resonance imaging. The combined analysis of all sequences was considered as the golden-standard. TSE sequences with long echo trains and b-FFE sequences were subjectively analyzed by two independent observers for differentiating cysts from hemangiomas. The kappa test (κ) was utilized in the analysis of the methods accuracy and inter- and intra-observer agreement (p < 0.05*). RESULTS: Cysts and hemangiomas dimensions ranged respectively between 0.5 and 6.5 cm (mean = 1.89 cm), and 0.8 and 11 cm (mean = 2.62 cm). The analysis of the sequences with long-TE and the golden-standard demonstrated a non-statistically significant agreement (κ: 0.00-0.10). The agreement between the evaluation of the b-FFE sequence and the golden-standard ranged from substantial (κ: 0.62-0.71) to almost perfect (κ: 0.86) for both observers. The inter- and intra-observer agreement for the b-FFE sequence ranged from substantial (κ: 0.62-0.70) to almost perfect (κ: 0.85-0.91). CONCLUSION: T2-weighted images acquired with the b-FFE technique present a high accuracy and reproducibility in the differentiation between cysts and hepatic hemangiomas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged, 80 and over , Cysts/diagnosis , Cysts/physiopathology , Hemangioma , Liver Neoplasms , Magnetic Resonance Imaging , Prospective Studies , Sensitivity and Specificity
3.
Radiol. bras ; 39(4): 259-262, jul.-ago. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-446540

ABSTRACT

OBJETIVO: Propor um modelo de padronização de relatório para aneurisma da aorta abdominal na tomografia computadorizada. MATERIAIS E MÉTODOS: Foram realizadas, no período de abril a outubro de 2004, entrevistas com integrantes da Disciplina de Cirurgia Vascular da nossa instituição, para elaboração de um modelo de padronização de relatório de tomografia computadorizada para o estudo do aneurisma da aorta abdominal. A partir deste modelo foi elaborado um questionário, enviado a nove outros cirurgiões, todos com experiência em cirurgia da aorta abdominal. O índice de resposta aos questionários foi de 55,5 por cento (5/9). RESULTADOS: Os parâmetros de interesse citados mais freqüentemente para a avaliação dos aneurismas de aorta abdominal foram: diâmetro máximo do colo proximal, extensão do colo proximal até a artéria renal mais baixa, forma do colo proximal, diâmetro máximo do aneurisma e diâmetro das artérias ilíacas comuns. Estes dados permitiram elaborar uma proposta de modelo para padronização de relatório na tomografia computadorizada. CONCLUSÃO: Um modelo para a análise tomográfica padronizada do aneurisma de aorta abdominal permite atender às necessidades dos cirurgiões vasculares para acompanhar a evolução e planejar o tratamento destes pacientes.


OBJECTIVE: To propose a model to standardize computed tomography reports on abdominal aortic aneurysms. MATERIALS AND METHODS: Interviews were carried out with members of Vascular Surgery Division of our institution, in the period between April and October 2004, aiming at developing a standardized model of computed tomography reports on abdominal aortic aneurysms. Based on this model, a questionnaire was elaborated and sent to other nine surgeons, all of them experienced in the field of abdominal aortic surgery. The questionnaires response rate was 55.5 percent (5/9). RESULTS: The most frequently mentioned parameters of interest for evaluation of abdominal aortic aneurysms were: maximum diameter of proximal aortic neck, proximal aortic neck length to lower renal arteries, shape of proximal aortic neck, maximum diameter of the aneurysm and diameter of the common iliac arteries. These data allowed the development of a proposal for a model to standardize computed tomography reports. CONCLUSION: A model for standardized tomographic analysis of abdominal aortic aneurysms has met vascular surgeons' needs for following-up patients and planning their treatment.


Subject(s)
Aorta, Abdominal , Outcome Assessment, Health Care , Research Report , Aneurysm/diagnosis , Identity and Quality Standard for Products and Services , Quality Control , Reproducibility of Results , Tomography, X-Ray Computed
SELECTION OF CITATIONS